Power over Ethernet and Snort
Summary: Cisco Talos researchers describe trying to place a Snort sensor inline with a PoE-powered wireless access point, and failing at first because the sensor could not supply power and the access point drew phantom power over the data pairs (1, 2, 3 and 6). They succeeded by using a VoIP phone dongle that moves power to the free pairs (4, 5, 7 and 8) and passes the 802.3af 25K ohm powered-device check, then wiring a four-port patch panel with a seven-dollar punch-down tool to route power around the sensor while data passed through it.
Key Takeaway: The workaround hinged on a 25K ohm resistance check in 802.3af: any inline device that does not present it gets no power at all, which is why the sensor could not simply sit in the line. The team also notes it NOPed out checks in Snort to allow an overly long content replace, a reminder that getting full traffic visibility sometimes means weakening the sensor itself.
Read the original at Cisco Talos ↗
- Topics
- Malware
- Related
- ARTEX and beyond: AI-enabled penetration testing platforms Cyber Risks · Nov 13, 2026Fake GTA 6 download goes after Steam logins and crypto wallet data Cyber Risks · Nov 13, 2026Operation Endgame Takes Down Gootloader, CastleRAT and StealC Servers, Seizes 6.4M Stolen Logins Cyber Risks · Nov 13, 2026